To Investigate the Refractive Index of Blood Plasma Suspended in Various Tonicity Solutions

Authors

  • Jogu Sumathi Biophysics Research Laboratory, Department of Physics, Nizam College, Osmania University, Hyderabad, Telangana, INDIA.
  • Zeeshan Ahmed Jaleeli MBBS, Osmania Medical College, Hyderabad, Telangana, INDIA.
  • Kaleem Ahmed Jaleeli Biophysics Research Laboratory, Department of Physics, Nizam College, Osmania University, Hyderabad, Telangana, INDIA.
  • Adeel Ahmad Biophysics Research Laboratory, Department of Physics, Nizam College, Osmania University, Hyderabad, Telangana, INDIA.

DOI:

https://doi.org/10.55544/jrasb.1.3.28

Keywords:

plasma from human blood, Profile of the refractive index, tonicity solutions, The Abbes’ refractometer

Abstract

This paper reports the data of the RI of plasma of normal blood, which is measured using Abbes' refractometer. The experimental values are compared to normal blood serum erythrocytes with Blood of Plasma suspended in various tonicity solutions between and 1.336 to 1.343, whereas the normal blood plasma refractive index is 1.351. As a result, the refractive index the worth of erythrocytes washed with different tonicity solutions are slightly lower than those of normal blood. If this optical parameter is standardized, it has the potential to be used as a tool in the medical field.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

Mohamed A. Elblbesy, Ther efractive index of human blood measured at the visible spectral region single - fiber reflectance spectroscopy, AIMS Biophysics, 8(1): 57–65. 2020 DOI: 10.3934/biophy.2021004

Wray JH, Neu JT (1969) Refractive index of several glasses as a function of wavelength and temperature. JOSA 59: 774–776.

Ding H, Lu JQ, Wooden WA, et al. (2006) Refractive indices of human skin tissues at eight wavelengths and estimated dispersion relations between 300 and 1600 nm. Phys Med Biol 51:1479.

Räty J, Pääkkönen P, Peiponen KE (2012) Assessment of wavelength dependent complex refractive index of strongly light absorbing liquids. Opt Express 20: 2835–2843.

Serbetçi Z, El -Nasser HM, Yakuphanoglu F (2012) Photoluminescence and refractive index dispersion properties of ZnO nanofibers grown by sol–gel method. Spectrochim Acta A 86:405–409.

Kim SH, Lee SH, Lim JI, et al. (2010) Absolute refractive index measurement method over abroad wavelength region based on white-light interferometry. ApplOptics49:910–914.

Shi W, Fang C, Yin X, et al. (1999) Refractive index dispersion measurement on nonlinear optical polymers using V-prism refractometer. Opt Laser Eng 32: 41–47.

Tuchin VV (2015). Tissue optics. Society of Photo -Optical Instrumentation Engineers (SPIE).

Meinke MC, Müller G J, Helfmann J, et al. (2007) Optical properties of platelets and blood plasma and their influence on the optical behavior of whole blood in the visible to near infrared wavelength range. J Biomed Opt 12: 014024.

Tuchin VV (2002) Handbook of optical biomedical diagnostics. SPIE-The International Society for Optical Engineering.

Wang J, Deng Z, Wang X, et al. (2015) Measurement of the refractive index of hemoglobin solution for a continuous spectral region. Biomed Opt Express 6: 2536–2541.

Bosschaart N, Edelman GJ, Aalders MCG, et al. (2014) A literature review and novel theoretical approach on the optical properties of whole blood. Laser Med Sci 29: 453–479.

Zhernovaya O, Sydoruk O, Tuchin V, et al. (2011). The refractive index of human hemoglobin in the visible range. Phys Med Biol56: 4013.

Rowe DJ, Smith D, Wilkinson JS (2017) Complex refractive index spectra of whole blood an aqueous solution of anticoagulants, analgesics and buffers in the mid-infrared. SciRep7: 1–9.

Taparia N, Platten KC, Anderson KB, et al. (2017). A microfluidic approach for hemoglobin detection in whole blood. AIP Adv 7:105102.

Serebrennikova YM, Huffman DE, Garcia-Rubio LH. (2015). Characterization of red blood cells with multi wavelength transmission spectroscopy. Bio Med Res Int

Ergül Ö, Arslan-Ergül A, Gürel L. (2010). Computational study of scattering from healthy and disease red blood cells. J Biomed Opt 15: 045004.

Zhang XU, Faber DJ, Post AL, et al. (2019). Refractive index measurement using single fiber reflectance spectroscopy. J Biophotonics12: e201900019

Vanessa Jirón ,Erick Castellón, The experimental average refractive index of liquid crystals and its prediction from the anisotropic indices. Phys. Chem. Chem. Phys., 24, 7788-7796.2022, https://doi.org/10.1039/D1CP04065K.

Zaky, Z. A., Panda, A., Pukhrambam, P. D. & Aly, A. H. The impact of magnetized cold plasma and its various properties in sensing applications. Sci. Rep. 12, 3754. https://doi.org/10.1038/s41598-022-07461-4 (2022).

Aly, A. H. et al. Novel biosensor detection of tuberculosis based on photonic band gap materials. Mater. Res. Ibero-am. J. Mater. 24, 2021. https://doi.org/10.1590/1980-5373-MR-2020-0483

El-Khozondar, H.J., Mahalakshmi, P., El-Khozondar, R.J., Ramanujam, N.R., Amiri, I., Yupapin, P.: Design of one-dimensional refractive index sensor using ternary photonic crystal waveguide for plasma blood samples applications. Phys. E 111, 29–36 (2019). https://doi.org/10.1016/j.physe.2019.02.030

Kushwaha, A.S., Kumar, A., Kumar, R., Srivastava, S.: A study of surface plasmon resonance (SPR) based biosensor with improved sensitivity. In: Photonics and Nanostructures-Fundamentals and Applications, vol. 31, pp. 99–106. https://doi.org/10.1016/j.photonics.2018.06.003 (2018).

Zaky, Z.A., Sharma, A., Aly, A.H.: Tamm plasmon polariton as refractive index sensor excited by Gyroid metals/porous Ta2O5 photonic crystal. Plasmonics (2021e). https://doi.org/10.1007/s11468-021-01559-7

Zaky, Z.A., Sharma, A., Alamri, S., Aly, A.H.: Theoretical evaluation of the refractive index sensing capability using the coupling of Tamm-Fano resonance in one-dimensional photonic crystals. Appl. Nanosci. 11, 2261–2270 (2021c). https://doi.org/10.1007/s13204-021-01965-7

Balakrishnan, S., Najiminaini, M., Singh, M.R., Carson, J.J.: A study of angle dependent surface plasmon polaritons in nano-hole array structures. J. Appl. Phys. 120, 034302 (2016). https://doi.org/10.1063/1.4958870

N. Manohar Redd, D. Kothandan, S. Chandra Lingam &Adeel Ahmad. International journal of innovative technology and creative engineering, August 2012, (ISSN:2045-8711) VOL.2 NO.8

Downloads

Published

2022-08-31

How to Cite

Sumathi, J., Jaleeli, Z. A., Jaleeli, K. A., & Ahmad, A. (2022). To Investigate the Refractive Index of Blood Plasma Suspended in Various Tonicity Solutions. Journal for Research in Applied Sciences and Biotechnology, 1(3), 216–221. https://doi.org/10.55544/jrasb.1.3.28